Filter Results By:

Products

Applications

Manufacturers

Transformer Test

Measure turns ratio, no-load current and winding resistance of transformers.

See Also: Transformers, Transformer Testers, Current Transformer Test, Current Transformer Test Set


Showing results: 271 - 285 of 412 items found.

  • Gas-Filled Hv Testing Transformer

    GTU-300KVA/600KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time. Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Inflatable High Voltage Testing Transformer

    GTU-250KVA/500KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Liquid Dielectric Test Cell

    LT-4123 - Lambient Technologies

    The LT-4123 Liquid Dielectric Test Cell is designed for testing the quality of materials such as the insulating oils used in transformers and the resins used in the manufacture of thermosets. With the LT-4123 Liquid Dielectric Test Cell, users can measure the AC loss characteristics and permittivity of liquids. The data gleaned from these measurements are used to set quality benchmarks for fluids during testing and manufacturing.

  • Current Booster

    BUX - Altanova Group

    The current boosters allow performing tests up to 2000A, 3000A and 5000A. The option is made of a module, which incorporates a power transformer, which generates a low-voltage, high current output and a metering CT, which measures the output current and sends the metering to eKAM.

  • Variable Frequency AC Resonant Test System

    HDXZ-162kVA/54kV - HD Power Test Equipment Co.ltd

    HDXZ-162kVA/54kV Variable Frequency AC Resonant Test System is applied for AC dielectric withstand test for electric equipment.The system is mainly composed of following parts:variable frequency control power supply,exciting transformer,reactor and capacitive divider.1. 10kV/300mm2 cable 3km AC withstand voltage test, capacitance ≤1.1265uF, test frequency 30-300Hz, test voltage 22kV, test time 5min.2. 35kV/300mm2 cable 1.5km AC withstand voltage test, capacitance ≤0.2917uF, test frequency 30-300Hz, test voltage 52kV, test time 60min.

  • Oil Test Set

    NEO TELE-TRONIX PVT. LTD

    We are the most reliable manufacturer and exporter of Oil Test Set that is ideal for testing of Breakdown / Withstand Test of Transformer and Circuit Breaker Oil. This test set is manufactured using premium quality raw material under the supervision of versed professionals. Moreover, the offered test set is checked by our quality inspectors on various parameters to ensure its flawlessness at clients' end. Our valuable clients can avail this Oil Test Set from us at competitive prices.

  • Resistance Measurement

    PROMET - KoCoS Messtechnik AG

    High-precision micro-ohm measuring systems with adjustable DC test current for determining resistances on circuit breakers or inductive loads such as transformers, for example. The high-precision ohm meters of the PROMET series are used to determine very low electrical resistances in the µΩ range. The adjustable test current of up to 600 A in combination with a four-wire measuring method delivers measurement results which meet stringent accuracy requirements. State-of-the-art power electronics coupled with a robust design guarantee excellent reliability for use as a portable device in switching stations and industrial environments. Typical applications include determining the contact resistance of switchgear devices and determining the resistance on inductive loads such as transformers.

  • Automatic Oil Tan Delta & Resistivity Kit

    MOTR - The Motwane Manufacturing Company

    Motwane's MOTR is multifunctional automatic test kit designed for accurate measurement of the Dielectric Constant, TanDelta, Resistivity & capacitance of transformer oil & other electrical insulating liquids. It has preprogrammed test sequences as per various International standards along with customized test sequences as per user requirements. Internal memory for 250 tests provided with PC interface & report generation facility. Inbuilt thermal printer for onsite results. Test cell is designed as per IEC247 with calibrator for onsite calibration of kit.

  • Computer Control 6-Phase Relay Protection Tester

    GDJB-PC6 - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1.This tester with standard 6 phase voltage, 6 phase current output,2.Voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A.3.Digital Signal Processor Microcomputer.4.Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TD Series - IBEKO Power AB

    Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • AC Resonant Test System

    Yangzhou Power Electric Co., Ltd

    Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.

  • 10 A portable digital micro-ohmmeter

    MPK-253 - MEGABRAS srl

    The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.

  • Primary Test Manager

    OMICRON electronics

    The Primary Test Manager™ (PTM) software supports you during diagnostic testing, condition assessment and data management of medium- and high-voltage assets, such as circuit breakers, rotating machines, grounding systems, instrument and power transformers as well as bushings and on-load tap changers (OLTC).

  • Transformer Oil Insulating Tester

    JY6601 - Kingrun Instrument Co., Ltd.

    JY6601 transformer oil insulating tester adopts completely new electromagnetic compatibility concept(EMC) which technology which will keep breakdown energy in a very low level,that will avoid pollution to oil sample during testing and make sure the test result are accurate and reliable.

  • Partial Discharge Test Set

    NEO TELE-TRONIX PVT. LTD

    We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.

Get Help